Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
2.
Int J Environ Res Public Health ; 19(16)2022 08 21.
Article in English | MEDLINE | ID: covidwho-2023676

ABSTRACT

Rapid scoring systems validated in patients with atrial fibrillation (AF) may be useful beyond their original purpose. Our aim was to assess the utility of CHA2DS2-VASc, HAS-BLED, and 2MACE scores in predicting long-term mortality in the population of the Bialystok Coronary Project, including AF patients. The initial study population consisted of 7409 consecutive patients admitted for elective coronary angiography between 2007 and 2016. The study endpoint was all-cause mortality, which occurred in 1244 (16.8%) patients during the follow-up, ranging from 1283 to 3059 days (median 2029 days). We noticed substantially increased all-cause mortality in patients with higher values of all compared scores. The accuracy of the scores in predicting all-cause mortality was also assessed using the receiver operator characteristic (ROC) curves. The greatest predictive value for mortality was recorded for the CHA2DS2-VASc score in the overall study population (area under curve [AUC] = 0.665; 95% confidence interval [95%CI] 0.645-0.681). We observed that the 2MACE score (AUC = 0.656; 95%CI 0.619-0.681), but not the HAS-BLED score, had similar predictive value to the CHA2DS2-VASc score for all-cause mortality in the overall study population. In AF patients, all scores did not differ in all-cause mortality prediction. Additionally, we found that study participants with CHA2DS2-VASc score ≥3 vs. <3 had a 3-fold increased risk of long-term all-cause mortality (odds ratio 3.05; 95%CI 2.6-3.6). Our study indicates that clinical scores initially validated in AF patients may be useful for predicting mortality in a broader population (e.g., in patients referred for elective coronary angiography). According to our findings, all compared scores have a moderate predictive value. However, in our study, the CHA2DS2-VASc and 2MACE scores outperformed the HAS-BLED score in terms of the long-term all-cause mortality prediction.


Subject(s)
Atrial Fibrillation , Stroke , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Coronary Angiography , Humans , Predictive Value of Tests , Risk Assessment , Risk Factors , Stroke/etiology
3.
Int J Cardiovasc Imaging ; 38(2): 351-362, 2022 Feb.
Article in English | MEDLINE | ID: covidwho-1427312

ABSTRACT

Transesophageal echocardiography (TEE) is the gold standard for assessing left atrial appendage (LAA) mechanic and thrombosis (LAAT); however, TEE is a high-risk procedure for viral transmission during coronavirus disease 2019 (COVID-19) pandemic. We investigated whether deformation indices of left atrium (LA) at transthoracic echocardiography (TTE) correlate with those of LAA assessed by TEE in nonvalvular atrial fibrillation (NVAF) patients undergoing electrical cardioversion (ECV). Consecutive patients with NVAF of ≥ 48 h or unknown duration, who underwent TEE and TTE at our Institution before ECV were retrospectively investigated. Standard echo-Doppler and LA and LAA myocardial strain and strain rate parameters were analyzed. A total of 115 NVAF patients (71.3 ± 8.1 yr/o, 59.1% men) were included: LAAT was diagnosed in 25 (21.7%) patients. Compared to patients without LAAT, those with LAAT had significantly higher CHA2DS2-VASc Risk score (4.5 ± 1.4 vs. 3.5 ± 1.1, p < 0.001), and lower ejection fraction (46.0 ± 14.8 vs. 57.6 ± 8.6%, p < 0.001). In LAAT patients, global strain of LA (8.7 ± 2.6 vs. 16.3 ± 4.5%, p < 0.001) and LAA (7.0 ± 1.7 vs. 11.7 ± 2.0%, p < 0.001) was significantly reduced compared to non-LAAT patients. A close relationship between left atrial strain reservoir (LASr) and LAA-global strain was demonstrated (r = 0.81). By univariable analysis, CHA2DS2-VASc Risk Score (OR 2.01, 95%CI 1.34-3.00), NT-proBNP (OR 1.36, 95%CI 1.19-1.54), ejection fraction (OR 0.92, 95%CI 0.88-0.96), E/e' ratio (OR 2.07, 95%CI 1.51-2.85), and LASr (OR 0.39, 95%CI 0.25-0.62) were strongly associated with LAAT presence at TEE. By multivariable analysis, only LASr (OR 0.40, 95%CI 0.24-0.70) retained statistical significance. ROC curve analysis revealed that an LASr cut-off value ≤ 9.3% had 98.9% sensibility and 100% specificity to identify LAAT by TEE (AUC = 0.98). In patients with NVAF of ≥ 48 h or unknown duration, scheduled to undergo ECV, LA deformation assessment by TTE might substitute invasive measurement of LAA function by TEE, simplifying diagnostic approach and possibly contributing to reduce COVID-19 infection diffusion.


Subject(s)
Atrial Appendage , Atrial Fibrillation , COVID-19 , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/complications , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/therapy , Echocardiography, Transesophageal , Electric Countershock/adverse effects , Female , Heart Atria/diagnostic imaging , Humans , Male , Pandemics , Predictive Value of Tests , Retrospective Studies , SARS-CoV-2
4.
J Cardiovasc Electrophysiol ; 32(12): 3125-3134, 2021 12.
Article in English | MEDLINE | ID: covidwho-1373828

ABSTRACT

BACKGROUND: Transesophageal echocardiography (TEE) is variably performed before atrial fibrillation (AF) ablation to evaluate left atrial appendage (LAA) thrombus. We describe our experience with transitioning to the pre-ablation cardiac computed tomography (CT) approach for the assessment of LAA thrombus during the COVID-19 pandemic. METHODS: We studied consecutive patients undergoing AF ablation at our center. The study cohort was divided into pre- versus post-COVID groups. The pre-COVID cohort included ablations performed during the 1 year before the COVID-19 pandemic; pre-ablation TEE was used routinely to evaluate LAA thrombus in high-risk patients. Post-COVID cohort included ablations performed during the 1 year after the COVID-19 pandemic; pre-ablation CT was performed in all patients, with TEE performed only in patients with LAA thrombus by CT imaging. The demographics, clinical history, imaging, and ablation characteristics, and peri-procedural cerebrovascular events (CVEs) were recorded. RESULTS: A total of 637 patients (pre-COVID n = 424, post-COVID n = 213) were studied. The mean age was 65.6 ± 10.1 years in the total cohort, and the majority were men. There was a significant increase in pre-ablation CT imaging from pre- to post-COVID cohort (74.8% vs. 93.9%, p ≤ .01), with a significant reduction in TEEs (34.6% vs. 3.7%, p ≤ .01). One patient in the post-COVID cohort developed CVE following negative pre-ablation CT. However, the incidence of peri-procedural CVE between both cohorts remained statistically unchanged (0% vs. 0.4%, p = .33). CONCLUSION: Implementation of pre-ablation CT-only imaging strategy with selective use of TEE for LAA thrombus evaluation is not associated with increased CVE risk during the COVID-19 pandemic.


Subject(s)
Atrial Appendage , Atrial Fibrillation , COVID-19 , Catheter Ablation , Thrombosis , Aged , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Echocardiography, Transesophageal , Female , Humans , Incidence , Male , Middle Aged , Pandemics , SARS-CoV-2 , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Tomography
5.
J Interv Card Electrophysiol ; 64(2): 383-391, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1298584

ABSTRACT

PURPOSE: Coronary artery calcium (CAC) and epicardial adipose tissue (EAT) can predict AF in the general population. We aimed to determine if CAC and EAT measured by computed tomographic (CT) scanning can predict new-onset AF in patients admitted with COVID-19 disease. METHODS: We performed a retrospective, post hoc analysis of all patients admitted to Montefiore Medical Center with a confirmed COVID-19 diagnosis from March 1st to June 23rd, 2020, who had a non-contrast CT of the chest within 5 years prior to admission. We determined ordinal CAC scores and quantified the EAT volume and examined their relationship with inpatient mortality. RESULTS: A total of 379 patients were analyzed. There were 16 events of new-onset AF (4.22%). Patients who developed AF during the index admission were more likely to be male (75 vs 47%, p < 0.001) and had higher EAT (129.5 [76.3-197.3] vs 91.0 [60.0-129.0] ml, p = 0.049). There were no differences on age (68 [56-71] vs 68 [58-76] years; p = 0.712), BMI (28.5 [25.3-30.8] vs 26.9 [23.1-31.8] kg/m2; p = 0.283), ordinal CAC score (3 [1-6] vs 2 [0-4]; p = 0.482), or prevalence of diabetes (56.3 vs 60.1%; p = 0.761), hypertension (75.0 vs 87.3%, p = 0.153), or coronary artery disease (50.0 vs 39.4%, p = 0.396). Patients with new-onset AF had worse clinical outcomes (death/intubation/vasopressors) (87.5 vs 44.1%; p = 0.001). CONCLUSION: Increased EAT measured by non-contrast chest CT identifies patients hospitalized with COVID-19 at higher risk of developing new-onset AF. Patients with new-onset AF have worse clinical outcomes.


Subject(s)
Atrial Fibrillation , COVID-19 , Adipose Tissue/diagnostic imaging , Aged , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , COVID-19 Testing , Female , Humans , Incidence , Male , Middle Aged , Pericardium/diagnostic imaging , Retrospective Studies , Risk Factors
6.
J Interv Card Electrophysiol ; 63(1): 97-101, 2022 Jan.
Article in English | MEDLINE | ID: covidwho-1064552

ABSTRACT

PURPOSE: Catheter ablation procedures for atrial fibrillation (AF) were significantly curtailed during the peak of coronavirus disease 2019 (COVID-19) pandemic to conserve healthcare resources and limit exposure. There is little data regarding peri-procedural outcomes of medical procedures during the COVID-19 pandemic. We enacted protocols to safely reboot AF ablation while limiting healthcare resource utilization. We aimed to evaluate acute and subacute outcomes of protocols instituted for reboot of AF ablation during the COVID-19 pandemic. METHODS: Perioperative healthcare utilization and acute procedural outcomes were analyzed for consecutive patients undergoing AF ablation under COVID-19 protocols (2020 cohort; n=111) and compared to those of patients who underwent AF ablation during the same time period in 2019 (2019 cohort; n=200). Newly implemented practices included preoperative COVID-19 testing, selective transesophageal echocardiography (TEE), utilization of venous closure, and same-day discharge when clinically appropriate. RESULTS: Pre-ablation COVID-19 testing was positive in 1 of 111 patients. There were 0 cases ablation-related COVID-19 transmission and 0 major complications in either cohort. Pre-procedure TEE was performed in significantly fewer 2020 cohort patients compared to the 2019 cohort patients (68.4% vs. 97.5%, p <0.001, respectively) despite greater prevalence of persistent arrhythmia in the 2020 cohort. Same-day discharge was achieved in 68% of patients in the 2020 cohort, compared to 0% of patients in the 2019 cohort. CONCLUSIONS: Our findings demonstrate the feasibility of safe resumption of complex electrophysiology procedures during the COVID-19 pandemic, reducing healthcare utilization and maintaining quality of care. Protocols instituted may be generalizable to other types of procedures and settings.


Subject(s)
Atrial Fibrillation , COVID-19 , Catheter Ablation , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , COVID-19 Testing , Humans , Pandemics , SARS-CoV-2 , Treatment Outcome
8.
J Investig Med High Impact Case Rep ; 8: 2324709620925571, 2020.
Article in English | MEDLINE | ID: covidwho-200453

ABSTRACT

The coronavirus disease-2019 (COVID-19) is an infectious disease caused by severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) that has significant potential cardiovascular implications for patients. These include myocarditis, acute coronary syndromes, cardiac arrhythmias, cardiomyopathies with heart failure and cardiogenic shock, and venous thromboembolic events. We describe a Caribbean-Black gentleman with COVID-19 infection presenting with atrial arrhythmias, namely, atrial flutter and atrial fibrillation, which resolved with rate and rhythm control strategies, and supportive care.


Subject(s)
Atrial Fibrillation/diagnosis , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/etiology , Atrial Fibrillation/therapy , Betacoronavirus , COVID-19 , Coronavirus Infections/complications , Coronavirus Infections/diagnostic imaging , Coronavirus Infections/therapy , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/complications , Pneumonia, Viral/diagnostic imaging , Pneumonia, Viral/therapy , SARS-CoV-2 , Thorax/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL